Ethernet Connector; Telco Alarms Connector; Ac Power Input For Ac-Input Power Supply; Figure 3-2. Telco Alarms Connector - Intel TIGPT1U - Carrier Grade Server Specification

Carrier grade server
Table of Contents

Advertisement

Cables and Connectors
3.4.5

Ethernet Connector

The server board SE7210TP1-E supports two NIC RJ45 connectors for the Ethernet ports. The
following table details the pin-out of each of the connectors.

Table 3-7. Magjack Connector (RJ45, 10/100/1000) Pin Out (J5A1, J6A2)

Pin
1
2
3
4
5
6
7
8
9
3.4.6

Telco Alarms Connector

The system provides one telco DB15 alarms connector on the rear bulkhead. Table 3-8 shows
the pinout for the telco alarms connector, and Figure 3-2 shows the telco alarms connector as
viewed from the back of the server.
Pin
1
2
3
4
5
6
7
8
3.4.7

AC Power Input for AC-Input Power Supply

One IEC320-C13 receptacle is provided at the rear of the AC-input power supply. It is
recommended to use an appropriately sized power cord and AC main. Please refer to Section
9, AC Power Subsystem, in this document for system voltage, frequency, and current draw
specifications.
28
Signal Name
LAN_V_1P8
LAN_MDI_2*
LAN_MDI_2
LAN_MDI_1
LAN_MDI_1*
LAN_V_1P8
LAN_V_1P8
LAN_MDI_3
LAN_MDI_3*

Table 3-8. Telco Alarms Connector

Description
MinorReset +
MinorReset -
MajorReset +
MajorReset -
CriticalAlarm - NO
CriticalAlarm - NC
CriticalAlarm - COM
MinorAlarm - NO
1
9

Figure 3-2. Telco Alarms Connector

®
Intel
Carrier Grade Server TIGPT1U TPS
Pin
Signal Name
10
LAN_MDI_0*
11
LAN_MDI_0
12
LAN_V_1P8
13
LAN_LINK_100*
14
LAN_LINK
15
LAN_LINK_UP*
16
LAN_ACTLED*
17
GND
18
GND
Pin
Description
9
MinorAlarm – NC
10
MinorAlarm - COM
11
MajorAlarm - NO
12
MajorAlarm - NC
13
MajorAlarm - COM
14
PwrAlarm - NO
15
PwrAlarm - COM
8
15
Revision 1.0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents