Malfunction
The unit does not report
an alarm.
Control of cameras or
other units is not
possible.
The unit is not
operational after a
firmware upload.
Placeholder with a red
cross instead of the
ActiveX components.
Web browser contains
empty fields.
Bosch Security Systems
Possible causes
Alarm source is not selected.
No alarm response specified.
The cable connection between
the serial interface and the
connected unit is not correct.
The interface parameters do not
match those of the other unit
connected.
Power failure during
programming by firmware file.
Incorrect firmware file.
JVM not installed on your
computer or not activated.
Active proxy server in network.
Installation and Operating Manual
Appendix | en 111
Recommended solution
Select possible alarm sources on
the Alarm Inputs configuration
page.
Specify the desired alarm
response on the Alarm
Connections configuration page,
change the IP address if
necessary.
Check all cable connections and
ensure all plugs are properly
fitted.
Make sure that the settings of all
units involved are compatible.
Have the unit checked by
Customer Service and replace if
necessary.
Enter the IP address of the unit
followed by /main.htm in your
Web browser and repeat the
upload.
Install Sun JVM from the
product CD.
Create a rule in the local
computer's proxy settings to
exclude local IP addresses.