Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1.
Unplug washer or disconnect power.
2.
Turn off the water supply to the washer.
3.
Remove the lower front access panel (see
step 10 on page 4-11 for the procedure).
4.
Using a shallow pan to catch the water,
unscrew the filter from the drain pump,
and drain the water from the pump.
Drain Pump Filter
REMOVING THE ECO VALVE
Drain Pump
5.
Pull the pressure hose off the air trap that
is connected to the pump-to-tub/ECO
valve hose.
6.
Loosen the clamps at both ends of the
pump-to-tub hose, and pull the hose/
ECO valve off the tub and drain pump.
Tub Clamp
Pump-To-Tub Hose
4-19
Pressure Hose
Pump Clamp
ECO Valve
Air
Trap