Figure 7. Mounting the fixed portion of the rail and the locking brackets to the rack
6. Install the outer (larger) slides in the rack, as shown in Figure 7.
7. Install the switch in the rack.
1) Washer, flat No. 8 10
2) Washer, lock No. 8 11
3) Nut, hex, 8-32 12
d. Repeat steps 5a on page 12 through 5c on page 12 for the three remaining
rail ends.
10
3
a. At the desired height, install the five M5 nut clips 5 . Put three M5 nut clips
in the front of the rack and two in the back. The middle clip in the front of
the rack is for the locking ears.
Note: Some rack mount kits might use 10-32 nut clips in place of the M5
nut clips for the locking ears.
b. Attach the slides by using four M5 x 12 screws 7 (see Figure 4 on page
10).
c. Repeat step 6a and step 6b for the other rail.
a. Position the switch in front of the rack. Insert the switch into the rack by
sliding the inner slides that are mounted on the switch into the outer slides
that are mounted on the rack. See Figure 8 on page 14.
4
1
9
SJ000048
Chapter 2. Installing and configuring the switch
13