82
C
8: M
HAPTER
AINTENANCE FOR THE
Figure 43 Location of the –48-volt DC Power Supply in an
8-slot Chassis
R
1
2
3
4
5
6
7
8-SL
C
OT
HASSIS AND THE
Power supply
slot 3
®
CoreBuilder
9000
8
9
10
ON
-48V
0V
STANDBY
INPUT RATING
-48 V
/27A
Power supply
(in slot 1)
Power supply
slot 2
16-S
C
LOT
HASSIS
For the 16-slot chassis only, to gain access to the
1
power supply slots, remove the plastic air grille bezel
that covers the power supply bay (Figure 37).
With both hands, hold each side of the bezel and
a
push down on the top of the bezel with your
thumbs.
b
Gently snap the bottom of the bezel off and then
the top.
For both an 8-slot chassis or 16-slot chassis, set the
2
power supply's Standby/On switch (Figure 44), which
is located on the front of the power supply, to the
Standby position.
Figure 44 –48-volt DC Power Supply Standby/On Switch
DC input
connector
Handle
ON
-48V
Standby/On
0V
switch
STANDBY
INPUT RATING
Spring-loaded
-48 V
/27A
screw