E.

Electrical System

1.
ADF Controller PCB
1) Remove the lower cover.
(See "B. External Covers.")
2) Disconnect the five connectors [1], and
remove the two screws [2]; then, remove
the ADF controller PCB [3].
2.
Original Placement Sensor and
Registration Paper Sensor
Pay attention to the colors of the cables
and connectors when connecting the connec-
tors of the original placement sensor and the
registration paper sensor.
Sensor
Original placement sensor
Registration paper sensor
Table 8-201
COPYRIGHT © 1999 CANON INC.
Cable color
Purple
Yellow
CANON PC800s/900s REV.0 AUG. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 8 ADF
[1]
[3]
[2]
[1]
Figure 8-232
Figure 8-233
[2]
Original
placement
sensor
Registration
paper sensor
8-33