Specifications
Environmental specifications
Specification
Temperature range*
Operating
Storage
Relative humidity**
Operating
Storage
Altitude ‡
Operating
Non-operating
* Temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed. The upper limit may be limited by the type and number of
options installed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.
‡ Maximum allowable altitude change rate is 457 m/min (1500 ft/min).
Storage array specifications
Specification
Height
Depth
Width
Weight (maximum)
Weight (no drives installed)
Value
10°C to 35°C (50°F to 95°F)
Maximum rate of change is 10º C/hr (50º F/hr)
-30°C to 60°C (-22°F to 140°F)
Maximum rate of change is 20º C/hr (68º F/hr)
10% to 90% relative humidity (Rh), 28º C (82.4º F)
maximum wet bulb temperature, non-condensing
5% to 95% relative humidity (Rh), 38.7º C (101.66º F)
maximum wet bulb temperature, non-condensing
3048 m (10,000 ft)
This value may be limited by the type and number of
options installed.
9144 m (30, 000 ft)
Value
22.10 cm (8.70 in)
89.12 cm (35.08 in)
44.70 cm (17.60 in)
145.15 kg (320.00 lb)
72.58 kg (160.00 lb)
Specifications 39