Specifications
HPE StoreEasy 1460 Storage specifications
HPE StoreEasy 1460 Storage environmental specifications
Specification
System Inlet Temperature
Operating
Extended Ambient Operating Temperature
Relative humidity (non-condensing)
Operating
Non-operating
Altitude
Operating
Non-operating
1
All temperature ratings shown are for sea level. An altitude derating of 1.0°C per 305 m (1.8°F per 1,000 ft) to 3,050 m (10,000 ft) is
applicable. No direct sunlight allowed. Maximum rate of change is 20°C per hour (36°F per hour). The upper limit and rate of change
might be limited by the type and number of options installed.
For certain approved hardware configurations, the supported system inlet temperature range is extended:
•
5°C to 10°C (41°F to 50°F) and 35°C to 40°C (95°F to 104°F) at sea level with an altitude derating of 1.0°C per every
175 m (1.8°F per every 574 ft) above 900 m (2,953 ft) to a maximum of 3,050 m (10,000 ft).
•
40°C to 45°C (104°F to 113°F) at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F per every 410
ft) above 900 m (2,953 ft) to a maximum of 3,050 m (10,000 ft).
28
Specifications
1
Value
—
10°C to 35°C (50°F to 95°F)
Maximum rate of change is 20°C/hr (36°F/hr). The upper
limit and rate of change may be limited by the type and
number of options installed.
System performance during standard operating support
may be reduced if operating with a fan fault or above 30°C
(86°F).
System performance may be reduced if operating in the
extended ambient operating range or with a fan fault.
—
8% to 90%. 28°C (82.4°F), maximum wet bulb temperature
5% to 95%, 38.7°C (101.7°F), maximum wet bulb
temperature
—
3050 m (10,000 ft). This value may be limited by the type
and number of options installed. Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable altitude change
rate is 457 m/min (1500 ft/min).