Installing A Hot-Plug Redundant Power Supply - HP DL360 - ProLiant - G3 Setup And Installation Manual

Hp proliant dl360 generation 3 server setup and installation guide
Hide thumbs Also See for DL360 - ProLiant - G3:
Table of Contents

Advertisement

Installing Hardware Options
5. Install the power supply fan baffle to the power converter housing by pushing in
until the tabs on the baffle snap into place on the housing.
Figure 2-18: Installing the power supply fan baffle
6. Set the Redundant Power Supply Install switch to On. Refer to SW1 settings in
Appendix E, "LEDs, Switches, and Jumpers."
7. Replace the access panel on the server, install the server in a rack and power up
the server. Refer to documentation that shipped with the server.

Installing a Hot-Plug Redundant Power Supply

IMPORTANT: This procedure assumes the server was previously configured for redundant
hot-plug power supplies.
1. If replacing an existing power supply, eject the power supply by grasping the
handle and pushing the power supply ejector button above the handle on the right
side.
2-22
When replacing a power supply, the surface may be hot
WARNING:
to the touch when first removed. To reduce the risk of injury from a
hot surface when handling the power supply, use the power supply
handle and other identified touch points.
HP ProLiant DL360 Generation 3 Server Setup and Installation Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant dl360 g3

Table of Contents