System Status Led - Bmc Initialization; Dimm Fault Leds; Figure 23. Dimm Fault Led Locations - Intel S5000XVNSATA Specification

Workstation board
Table of Contents

Advertisement

Intel® Workstation Board S5000XVN TPS
Intel® Light Guided Diagnostics
7.3.1
System Status LED – BMC Initialization
When the AC power is first applied to the system and 5V-STBY is present, the BMC on the
server board requires 20-30 seconds to initialize. During this time, the system status LED will
blink, alternating between amber and green, and the power button functionality of the control
panel is disabled, preventing the server from powering up. Once BMC initialization is completed,
the status LED will stop blinking and the power button functionality is restored and can be used
to turn on the server.
7.4

DIMM Fault LEDs

The workstation board provides a memory fault LED for each DIMM socket. These LEDs are
located towards the rear of the server board next to each DIMM connector.
AF001034

Figure 23. DIMM Fault LED Locations

Revision 1.5