Figure 5
shows the BBU mounting dimensions for the Total Access 904/908.
For a wallmount installation, the BBU installs on heavy plywood (3/4-inch minimum) using two
#10 x 3/4-inch pan-head wood screws. Install the BBU as follows:
Step
1
Determine the preferred unit layout to ensure cable plugs reach their designated sockets.
2
Ensuring a plumb measurement, mark where the pilot holes are to be drilled according to the
dimensions given in the documentation included with your shipment.
3
Drill the two pilot holes using a size 1/16-inch drill bit.
4
Screw in the top two pan-head screws that fit the keyhole openings. Let the head of each
screw protrude 1/16 inch from the plywood to engage the keyhole slot.
5
Position the BBU and to hang on the screw heads. Allow the unit to slide down until the slot
end rests against the screws.
6
Use cable ties as appropriate. The battery connection from the BBU should be directly
connected to the BATT port on the rear of the chassis.
61210916L1-34G
TOP of Unit
2.734 "
edge-to-center
4.280 "
center-to-center

Figure 5. Wall Mounting the 1200641L1 BBU