Table 8

Event severity levels

Icon and level
Critical (1)
Error (2)
Warning (3)
Info (4)

Displaying fabric events

Events are displayed for all switches in the fabric in the Fabric Events window (see
events are not polled. You must click Refresh from the Fabric Events window to poll fabric events. Switch
events are polled every 15 seconds.
Fabric Events can be collected only for switches that have the same security level (http or https) as the
launch switch. For switches that have a different level of security from the launch switch, a message is
displayed at the top of the window indicating how many switches have no events reported from the last
polling. For detailed information on the switch names and reasons for not polling (if available), click
Details.

To display fabric events

1.
Click a fabric from the Fabric Tree.
2.
Click the Fabric Events icon
The Fabric Events window is displayed (see
3.
Optional: Click the column head to sort the events by a particular column.
Drag the column divider to resize a column.
You can also filter events, as described in
Description
Critical-level messages indicate that the software has detected serious problems that will
eventually cause a partial or complete failure of a subsystem if not corrected immediately. For
example, a power supply failure or rise in temperature must receive immediate attention.
Error-level messages represent an error condition that does not significantly affect overall
system functionality. For example, error-level messages might indicate timeouts on certain
operations, failures of certain operations after retries, invalid parameters, or failure to
perform a requested operation.
Warning-level messages highlight a current operating condition that should be checked or it
might lead to a failure in the future. For example, a power supply failure in a redundant
system relays a warning that the system is no longer operating in redundant mode and that
the failed power supply needs to be replaced or fixed.
Information-level messages report the current nonerror status of the system components, for
example, the online and offline status of a fabric port.
on the Fabric Toolbar.
"Filtering fabric and switch
Figure
13).
events" on page 53.
Fabric OS 5.x Advanced Web Tools administrator guide
Figure
13). Fabric
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks fabric os 5 advanced web tools

Table of Contents