Configuring Fabric Watch thresholds

The Threshold Configuration tab enables you to configure event conditions. From this tab, you configure
threshold traits, alarms, and e-mail configuration.
Use the following procedures to configure threshold traits for all classes except for the FRU class. Use the
procedure described in

Configuring threshold traits

Configure threshold traits to define a threshold for a particular class and area. Using the following
procedure, you can configure the following traits for a threshold:
Unit: The string used to define the units of measurement for the area
Time Base: The time base (second, minute, hour, day) for the area
Low Boundary: The low threshold for the event-setting comparisons
High Boundary: The high threshold for the event-setting comparisons
Buffer Size: The size of the buffer zone used in event-setting comparisons

To configure threshold traits

1.
Launch the Fabric Watch module as described in
page 122.
2.
Click the Threshold Configuration tab (see
Figure 48

Threshold configuration for Fabric Watch

3.
Click the Trait Configuration subtab.
4.
Click a class from the Fabric Watch navigation tree.
NOTE:
If you select the FRU class from the Fabric Watch navigation tree, there is a separate set of
instructions. See
"Configuring alarms for
"Configuring alarms for
FRUs" on page 125 for the FRU class.
"Launching the Fabric Watch
Figure
48).
FRUs" on page 125.