PLV-WF20 Expand Serial Command Functional Specifications
8.7.6 CF_REAR Command
Command
"CF_REAR_%1" [CR]
"ON" --------------------------- Set Rear to ON
%1
"OFF" ------------------------- Set Rear to OFF
Set/Cancel Rear. (Valid only when in the normal Power ON status.)
When Rear is set to ON, image is left/right reversed.
Details
The status set by this command is stored in EEPROM and the setting remains
effective after the power is turned to ALL OFF status.
Acceptable
Response
Unacceptable
8.7.7 CF_VSCALE Command
Command
%1
Details
Response
8.7.8 CF_VPOS Command
Command
%1
Details
Response
"000" [CR]
"Error Code" [CR]
"CF_VSCALE_%1" [CR]
"035" ---------------------- +35
"031" ---------------------- +31
:
"001" ---------------------- +1
"000" ---------------------- ±0
"‐01" ---------------------‐1
:
"‐31" ---------------------‐31
"‐32" ---------------------‐32
"UP" --------------------- Increment setting value of Vscale by 1
"DN" --------------------- Decrement setting value of Vscale by 1
Set Vscale (Available only in the normal Power ON status)
*When selected screen mode is a setting except Custom, return "101" [CR] and
the command is not executed.
* When input is no signal, return "101" [CR] and the command is not executed.
Acceptable
"000" [CR]
Unacceptable
"Error Code" [CR]
"CF_VPOS_%1" [CR]
"015" --------------------- +15
"014" --------------------- +14
:
"001" --------------------- +1
"000" --------------------- ±0
"‐01" ---------------------‐1
:
"‐14" ---------------------‐14
"‐15" ---------------------‐15
"UP" --------------------- Increment setting value of Vposition by 1
"DN" --------------------- Decrement setting value of Vposition by 1
Set V Position (Available only in the normal Power ON status)
*When selected screen mode is a setting except Custom, return "101" [CR] and
the command is not executed.
* When input is no signal, return "101" [CR] and the command is not executed.
Acceptable
"000" [CR]
Unacceptable
"Error Code" [CR]
31/68