Cr_Inflamp Command; Cr_Projh Command; Cr_Hmlamp Command; Cr_Lamph Command - Sanyo PLV-WF20 - 6000 Lumens Manual

External special command functional specifications
Hide thumbs Also See for PLV-WF20 - 6000 Lumens:
Table of Contents

Advertisement

PLV-WF20 Expand Serial Command Functional Specifications

9.9.5 CR_INFLAMP Command

Command
"CR_INFLAMP" [CR]
Details
Get Lamp mode switching status
Acceptable
Response
Unacceptable

9.9.6 CR_PROJH Command

Command
"CR_PROJH" [CR]
Details
Get total running time of projector (in hours)
Acceptable
Response
Unacceptable

9.9.7 CR_HMLAMP Command

Command
"CR_HMLAMP" [CR]
Details
Get total lamp number
Acceptable
Response
Unacceptable

9.9.8 CR_LAMPH Command

Command
"CR_LAMPH" [CR]
Get Lamp running time (in hours)
Details
* return actual lamp running time
Acceptable
%1_%2
Response
%3_%4
Unacceptable
"000_%1" [CR]
"NML" --------- in Normal status (lamp switching operation is not
%1
active.)
"CNG" ---------- during lamp switching operation
"?" [CR]
"000_%1" [CR]
%1
"0000000" – "0099999"
"?" [CR]
"000_%1" [CR]
%1
"002"
"?" [CR]
"000_%1_%2_%3_%4" [CR]
Lamp 1 data comes first, and then one space, after that lamp 2
data is followed.
%1 = lamp No.1
%2 = lamp No.2
%3 = lamp No.3
%4 = lamp No.4
※ In the case of 2-lamps model, % 1 and % 2 are only used
(There are no % 3 and % 4)
eg; "0410_0410_0410_0410" [CR]
▪▪▪▪ → Lamp No.1 = 410 Hours
Lamp No.2 = 410 Hours
Lamp No.3 = 410 Hours
Lamp No.4 = 410 Hours
Note;
-each data shall be 4 digits.
-"9999" is returned for 10000 hours or more.
"Error Code" [CR]
57/68

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plv-wf20

Table of Contents