PLV-WF20 Expand Serial Command Functional Specifications
9.5 PC Status Read Commands
9.5.1 CR_FSYNC Command
Command
"CR_FSYNC" [CR]
Details
Get value of Fine Sync
Acceptable
Response
Unacceptable
9.5.2 CR_TDOTS Command
Command
"CR_TDOTS" [CR]
Details
Get value of Total Dots
Acceptable
Response
Unacceptable
9.5.3 CR_H-POS Command
Command
"CR_H-POS" [CR]
Details
Get value of Horizontal Position
Acceptable
Response
Unacceptable
9.5.4 CR_V-POS Command
Command
"CR_V-POS" [CR]
Details
Get value of Vertical Position
Acceptable
Response
Unacceptable
"000_%1" [CR]
%1
"0000" – "0031"
"Error Code" [CR] -------------- When command is invalid in the
given condition (such as being selected input)
"?" [CR] --------- When unknown command is received
"000_%1" [CR]
"mmmm" – "nnnn"
%1
(mmmm = Display area H + Position H)
(nnnn = Maximum value less than 140 MHz of Dot Clock)
"Error Code" [CR] -------------- When command is invalid in the
given condition (such as being selected input)
"?" [CR] --------- When unknown command is received
"000_%1" [CR]
"0000" – " nnnn"
%1
(nnnn = Total Dots - Display Area H)
"Error Code" [CR] -------------- When command is invalid in the
given condition (such as being selected input)
"?" [CR] --------- When unknown command is received
"000_%1" [CR]
"0000" – " nnnn"
%1
(nnnn = Total Line - Display Area V)
"Error Code" [CR] -------------- When command is invalid in the
given condition (such as being selected input)
"?" [CR] --------- When unknown command is received
45/68