PLV-WF20 Expand Serial Command Functional Specifications
9.10.20 CR_FILCOND Command
Command
"CR_FILCOND" [CR]
Details
Get status of filter clog
Acceptable
Response
Unacceptable
9.10.21 CR_FILREPL Command
Command
"CR_FILREPL" [CR]
Details
Get status of Filter cleaning / replacement time
Acceptable
Response
Unacceptable
9.10.22 CR_FILTIMER Command
Command
"CR_FILTIMER" [CR]
Details
Get time to display Filter cleaning / replacement warning on screen
Acceptable
Response
Unacceptable
9.10.23 CR_FILREMAIN Command
Command
"CR_FILREMAIN" [CR]
Details
Get remaining number of usable Filter scroll
Acceptable
Response
Unacceptable
"000_%1" [CR]
"CLOG" = Filter is clogged
%1
"WARN" = Filter is nearly clogged
"CLEAN" = Filter is not clogged
"Error Code" [CR]
"000_%1" [CR]
"1Y"-------Filter Exchange time is over value of Filter Message.
%1
"1N"--Filter Exchange time is not over value of Filter Message.
"Error Code" [CR]
"000_%1" [CR]
"0400" ---------------------- Display massage by 400h used.
"0700" ---------------------- Display massage by 700h used.
%1
"1000" ---------------------- Display massage by 1000h used.
"OFF" ---------------------- Off(Warning display is not displayed)
"Error Code" [CR]
"000_%1" [CR]
"09" = Remaining number of usable Filter scroll : 9 times
%1
:
"00" = Remaining number of usable Filter scroll : 0 time
"Error Code" [CR]
62/68