PLV-WF20 Expand Serial Command Functional Specifications
9.10.10 CR_P-MANETIME Command
Command
"CR_P-MAETIME" [CR]
Details
Get setting time for starting Power Management function
Acceptable
Response
Unacceptable
9.10.11 CR_FANSPEED Command
Command
"CR_FANSPEED" [CR]
Details
Get currently selected Fan Control Speed
Acceptable
Response
Unacceptable
9.10.12 CR_KEYDIS Command
Command
"CR_KEYDIS" [CR]
Details
Get setting status of RC/KEY use limitation (valid or invalid)
Acceptable
Response
Unacceptable
9.10.13 CR_SHUTRCPROT Command
Command
"CR_SHUTRCPROT" [CR]
Details
Get status if Shutter can be controlled by R/C
Acceptable
Response
Unacceptable
9.10.14 CR_SHUTKEYPROT Command
Command
"CR_SHUTKEYPROT" [CR]
Details
Get status if Shutter can be controlled by key on the top panel
Acceptable
Response
Unacceptable
"000_%1" [CR]
%1
"001 – 030" ----------------------- 1 to 30 minutes
"?" [CR]
"000_%1" [CR]
"MAX" -------------------- Max speed of Fan Control is selected
%1
"NOR" -------------------- Normal speed of Fan Control is selected
"?" [CR]
"000_%1" [CR]
"NONE" ------------------------- RC & KEY are valid
%1
"RC" ----------------------------- RC is invalid
"KEY" --------------------------- KEY is invalid
"?" [CR]
"000_%1" [CR]
"ON" -------------------- Shutter is not controllable by R/C
%1
"OFF" ------------------- Shutter is controllable by R/C
"?" [CR]
"000_%1" [CR]
"ON" ------------- Shutter is not controllable by key on the top panel
%1
"OFF" ------------ Shutter is controllable by key on the top panel
"?" [CR]
60/68