Motorola V186 - Cell Phone - GSM System Planner Manual page 157

Remote terminal unit (rtu)
Hide thumbs Also See for V186 - Cell Phone - GSM:
Table of Contents

Advertisement

18-72V DC Power Supply Modules
Input Voltage
Total Power
Outputs
Battery Charger
Diagnostic LEDs
No Load Power
Consumption
Efficiency
Inrush Current
Protection
Output Protection
Insulation
Dimensions
Weight
Specifications subject to change without notice.
18-72 V DC
18-72 V DC Max. 60 W continuous; max. 105 W peak @ 25% duty cycle
Motherboard connector (to CPU and I/O modules): 13.2 V DC ±20%,
max. 4 A
AUX1A/AUX1B: equal to input voltage, max. 8 A, on/off controlled by
user program
AUX2A/AUX2B (configurable): equal to input voltage (default), max.
8A,
or 3.3 (default), 5, 7.5, 9 V DC ±10%, max. 2.5A, on/off (default)
controlled by user program
Note: max. 8 A total current consumption from all outputs
12 V Lead Acid battery charger (in PS model with charger)
Automatic charging of 6.5 or 10 Ah backup battery, battery temperature
sensing, overcharging protection, battery capacity test and diagnostics,
automatic battery switch-over
Status LED for: input voltage, AUX1 and AUX2 outputs, 12 V Control
DO for DO modules, and battery
Max. 250 mA
80% typical, 76% with full load
10 A maximum, for 2 mSec. Max, cold start at 25°C
Internal line input fuse (replaceable), short circuit automatic recover
AUX2A/B short circuit, automatic recovery on 3.3, 5, 7.5, 9 V
Input to case: 500 V DC, input to output 500 V DC
56 mm W x 225 mm H x 180 mm D (2.2" W x 8.7" H x 7.1" D)
Approx. 1Kg (2.2 Lb)
Appendix A – ACE3600 Specifications
153

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ace3600

Table of Contents