Ensure the monitor cables and mouse cables are long enough to allow the
NetServer to be extended at the same time the keyboard tray is pulled out.
Use locally available extensions if necessary.
The mounting distances provided in rack configuration tools assume cables
between the servers and connected devices provide for the Cable
Management Arm (for the LC 2000r).

Cooling Requirements for the LC 2000r

For optimum operational results, the HP NetServer LC 2000r should be kept at an
operating temperature between 68 and 72 degrees F. Minimally, the interior of the
NetServer must be kept between 41 and 95 degrees F (5 - 35 degrees C.)
Remember that ambient temperatures may be lower than the temperature inside
the server.
Because of the heat generated by the HP NetServer LC 2000r, both the front and
rear doors of the rack must have perforated surfaces. (Alternatively, both front and
rear doors can be left off the rack.) Air flow in racked units flows through front
and rear. If you are installing the HP NetServer LC 2000r in a rack that has solid
front and rear doors, you must either replace the doors on your rack with
perforated doors or remove solid doors to ensure proper air flow.
Because of the high capacity fans installed in the HP NetServer LC 2000r, no
external (rack) exhaust fan is needed with this unit. The rack must have perforated
front and rear doors, or no doors.