HP BladeSystem bc2800 - Blade PC Reference Manual page 61

Service reference guide: hp bladesystem pc blade enclosure g2 assemblies
Hide thumbs Also See for BladeSystem bc2800 - Blade PC:
Table of Contents

Advertisement

Table 7-5
Is the Enclosure Health LED on the Front of the Enclosure On? (continued)
Yes, it is red.
Yes, it is green.
Table 7-6
Is the Local Management Console Displaying Information When Connected to the Enclosure?
Answer
No.
Yes.
Table 7-7
Is the Integrated Administrator Health LED Green?
Answer
No, it is off.
No, it is amber.
A system component has a critical
failure.
The Integrated Administrator has not
detected any degraded or failed
components.
Possible Reasons
The local management console may not
be connected properly.
The Integrated Administrator module
has failed.
The Integrated Administrator firmware
may be damaged.
Video is available for diagnosis. Determine the next action by observing POST progress and
system event logs. Refer to
POST Error Messages on page 44
each POST error message.
Possible Reasons
The Integrated Administrator is booting.
Software has detected a condition
within the Integrated Administrator that
requires attention.
Check your local or remote console for error
messages. Go to
Table 7-6 Is the Local
Management Console Displaying Information
When Connected to the Enclosure? on page
Check system fans. Go to
Table 7-8 Is the Fan
Health LED Green? on page 56
Contact HP or your authorized service provider for
parts and service.
Check your local or remote console for error
messages. Go to
Table 7-6 Is the Local
Management Console Displaying Information
When Connected to the Enclosure? on page 55
Contact HP or your authorized service provider for
parts and service.
Possible Solutions
Be sure that the local management console cable
is securely connected.
Go to
Table 7-7 Is the Integrated Administrator
Health LED Green? on page 55
If these steps do not solve the problem, contact
HP or your authorized service provider for
assistance.
for a complete description of
Possible Solutions
If the enclosure is powered up, wait one minute
while the Integrated Administrator is booting. If the
Integrated Administrator health LED remains off,
contact HP or your authorized service provider for
parts and service.
Press the reset button on the Integrated
Administrator.
Check the system fans. Go to
Health LED Green? on page 56
Contact HP or your authorized service provider for
parts and service.
Enclosure diagnostic steps
55.
Table 7-8 Is the Fan
55

Advertisement

Table of Contents
loading

Table of Contents