POST Error Messages
Code/Message
6920-Processor in Force-
Throttle Mode
6921-Blade System
Management Controller
firmware update failed
6922-Blade temperature
detected to be below 0 degrees
Celsius
6923-CPU Temperature
Monitoring Hardware failure
6924-Graphics Temperature
Monitoring Hardware failure
6925-Blade/Enclosure
Communication error
6927-Previous POST under
Recovery BIOS.
6928-POST under Recovery
BIOS image.
6929- Blade performance is
reduced due to insufficient
enclosure power and/or
cooling.
6931-BIOS unable to update
BMC Primary Firmware
48
Chapter 6 POST Error Messages
Health LED
Possible Cause
Amber
Enclosure or
environmental issue.
Amber
The flashing process
was interrupted.
Amber
The blade PC is
operating in
temperatures below
specification.
Red
CPU temperature
monitoring hardware
has failed.
Red
System graphics
temperature
monitoring hardware
has failed.
Amber
Potential enclosure or
blade PC issue.
Green
Previous POST under
Recovery BIOS.
Amber
POST under Recovery
BIOS image.
Amber
Blade was a bc2800
and inserted into an
enclosure that cannot
support full processor
performance.
Red
Three consecutive
attempts to update the
BMC firmware failed
during POST.
Recommended Action
Ensure the enclosure health LED is green
and health status is OK. If LED not green,
troubleshoot the enclosure. For
troubleshooting information, see
Troubleshooting on page
If the enclosure health LED is green, check
heatsink installation and operating ambient.
Make sure every enclosure slot is filled with
a blank or a blade PC.
Re-flash the BMC firmware image.
Check operating ambient. Operate the blade PC
within environmental specifications.
Replace the blade PC.
Replace the blade PC.
Swap the blade PC to a different bay in the
enclosure and retest.
Put the blade PC into a different enclosure.
If the blade PC works in a different
enclosure, troubleshoot the original
enclosure. For troubleshooting information,
see
Troubleshooting on page
Replace the blade.
Informational message only.
Re-flash the BIOS.
If the problem persists, replace the blade
PC.
Power off blade and remove blade, or update
enclosure Integrated Administrator firmware to
version 4.30 or greater, or update enclosure to
HP BladeSystem PC Blade Enclosure G2.
BIOS 3.xx introduces BIOS BMC Firmware
Updating. This feature links the BIOS version to
the BMC firmware version. The BMC firmware is
updated during BIOS POST. BIOS will attempt
to update the BMC firmware 3 times before
booting to an OS without successfully updating
the BMC firmware.