PRINTER SPECIFICATIONS AND REQUIREMENTS
Outlet configurations
Printer outlet voltages—60 Hz
Printer power cord configurations
6-2
XEROX DOCUPRINT NETWORK PRINTER SERIES INSTALLATION PLANNING GUIDE FOR MODELS 4050/4090 NPS
This section discusses specifications for the DocuPrint system
outlets and the required wall outlet configurations for the U. S. /
Canada and internationally.
Note: All power outlets must be dedicated to this equipment. When
determining the electrical connections for your system, make sure
that:
Each power cord has a separate circuit
The printer power cord configurations match your receptacle
Your electrical outlets are within the required specifications.
50 Hz systems: Ensure that power connections are per local codes/
regulations.
The following table shows the voltages for the outlets on your printing
system. All power outlets must have a dedicated circuit for each
system equipment piece.
Table 6-5.
60 Hz voltage requirements at power outlet
Measurement of wiring
Line 1 to neutral
Line 2 to neutral
Neutral to ground
Line 1 to line 2
Line 1 to ground
Line 2 to ground
The following figure shows the 60 Hz power cord configuration for 30
amp NEMA 14-30R. Voltage to ground is shown for troubleshooting
purposes.
Figure 6-1.
60 Hz power configuration
NEMA
14-30R
181 to 220 VAC
Nominal
Range
120 V
105 to 127 V
120 V
105 to 127 V
0 V
0 to 10 V
208 V
181 to 220 V
120 V
105 to 127 V
120V
105 to 127 V
105 to 127 VAC
0 to 10 VAC
105 to
105 to 127 VAC
127 VAC
Neutral
Line 1
Ground
105 to 127 VAC
Line 2