• Changing Switch Settings on Pan/tilt Head
q Remove the cover from the pan/tilt head.
* Be careful of the Tally Indicator wire.
w Shift the mounting direction switches (SW1, SW2) on
the pan/tilt head depending on whether the head is
suspended from the ceiling or mounted on the floor.
They are originally set for suspended installation.
* Do not change the original set position of SW3. If it is
changed, no operation can be controlled from the con-
trol panel.
e Place the cover back on the pan/tilt head.
* Be sure not to trap the wires.
Tally Indicator
• If the pan/tilt head is connected to the multiport hub
-20-
SW 1
SW 2
SW 3
with a cable longer than 300 meters, set the cable
compensation switch on the pan/tilt head to the ON
position in advance.
If the distance between the
pan/tilt head and the control panel is shorter than 300
meters, keep the switch in the original position (OFF).
For details on shifting the switch, refer to the figure
below or the Operating Instructions for Pan/tilt Head.