Verifying The Switch Mode - Dell PowerEdge M420 Administrator's Manual

8/4 gbps fc san module administrator's guide
Hide thumbs Also See for PowerEdge M420:
Table of Contents

Advertisement

4
Fabric and Edge switch configuration
Before connecting the FC SAN Module to Brocade switches, disable the Brocade Fabric OS
Management Server Platform Service to get accurate statistical and configuration fabric data,

Verifying the switch mode

1. Connect to the switch and log in using an account assigned to the admin role.
2. Enter the switchShow command to display the current switch configuration.
26
If DCC security is being used on Edge switches that directly connect to the FC SAN Module,
make sure to include the module WWN or the port WWN of the external ports (N_Ports). Also
include the HBA WWNs that will be connected to internal ports (F_Ports) to the ACL list in the
ACL policy. It is recommended to use FC SAN Module ADS policy instead of the DCC policy on
the Edge switch.
Allow inband queries for forwarded fabric management requests from the hosts. Add the FC
SAN Module WWN to the access list if inband queries are restricted.
The following example shows a switch in the Fabric OS Native mode where switchMode
displays as Native.
switch:admin> switchshow
switchName:
switch
switchType:
43.2
switchState:
Online
switchMode:
Native
switchRole:
Principal
switchDomain:
1
switchId:
fffc01
switchWwn:
10:00:00:05:1e:03:4b:e7
zoning:
OFF
switchBeacon:
OFF
Area Port Media Speed State
=====================================
0
0
--
N4
1
1
cu
N4
2
2
cu
N4
3
3
cu
AN
4
4
cu
AN
5
5
cu
N4
6
6
cu
N4
7
7
cu
AN
8
8
cu
AN
9
9
cu
AN
10
10
cu
AN
11
11
cu
AN
12
12
cu
AN
13
13
cu
AN
14
14
cu
AN
15
15
cu
AN
16
16
cu
AN
17
17
--
N4
18
18
--
N4
19
19
--
N4
20
20
--
N4
21
21
id
N4
Online
master)
22
22
id
N4
Online
Proto
No_Module
Online
F-Port
Online
F-Port
No_Sync
No_Sync
Disabled (Persistent)
Online
F-Port
Online
F-Port
No_Sync
Disabled (Persistent)
No_Sync
No_Sync
Disabled (Persistent)
No_Sync
Disabled (Persistent)
No_Sync
Disabled (Persistent)
No_Sync
Disabled (Persistent)
No_Sync
Disabled (Persistent)
No_Sync
Disabled (Persistent)
No_Sync
Disabled (Persistent)
No_Sync
Disabled (Persistent)
No_Module
No_Module
No_Module
No_Module
E-Port
E-Port
Dell 8/4Gbps FC SAN Module Administrator's Guide
50:06:0b:00:00:3c:b7:32
10:00:00:00:c9:35:43:f5
50:06:0b:00:00:3c:b4:3e
10:00:00:00:c9:35:43:f3
segmented,(zone conflict)(Trunk
(Trunk port, master is Port 21 )
53-1001345-01

Advertisement

Table of Contents
loading

Table of Contents