Port part of other AD
portSpeed
LE domain
FC Fastwrite
If the port is configured as an EX_Port, the following additional port information is displayed:
EX_Port Mode
Fabric ID
Front Phantom
Pr Switch Info
BB XLate
Authentication Type
DH Group
Hash Algorithm
Edge fabric's primary WWN
Edge fabric's version stamp
If the port is configured as a VE_Port, the command shows FC and Physical layer attributes of the
underlying port, as well as status information regarding the underlying FCIP link for those logical FC
ports that are instantiated over a physical 1/10GbE port. Refer to the example section for an
illustration.
Following the general information, the command displays three columns of counters. The first
column shows interrupt statistics:
Interrupts
Unknown
Dell 8/4Gbps FC SAN Module Administrator's Guide
53-1001345-01
Yes or No.
The port's fixed speed (1, 2, 4, or 8 Gbps) or negotiated speed (N1 Gbps, N2
Gbps, N4 Gbps, N8 Gbps or AN).
The LE domain ID.
The status of FC Fastwrite (ON or OFF).
The port is configured as an EX_Port.
The fabric ID assigned to this EX_Port; this is the fabric ID of the edge fabric
attached to this EX_Port.
Information on the front phantom domain presented by this EX_Port. Includes
the preferred (if not active) or actual (if active) domain ID for the front domain
and the WWN of the front domain.
Information on the principal switch of the edge fabric attached to this
EX_Port. Includes the domain ID and WWN of the principal switch.
Information on the xlate (translate) phantom domain presented at this port.
Includes the preferred (if not active) or actual (if active) domain ID for the
xlate phantom domain and the WWN of the xlate phantom domain. The xlate
phantom domain connected at this port is in the same fabric as the router
and represents the edge fabric connected to the EX_Port.
Displays NONE or DH-CHAP. DH-CHAP is the only authentication type
supported on EX_Ports.
Displays DH group [0-4] if DH-CHAP authentication is used. Otherwise
displays N/A.
Displays hash type (MD5 or SHA-1) if DH-CHAP authentication is used.
Otherwise, displays N/A.
If the EX_Port is connected to an edge switch with FCS policy enforcement,
the WWN of the primary FCS is displayed when the edge fabric is secure and
the primary FCS is online. Otherwise, displays "No Primary".
If the EX_PORT is connected to an edge switch with FCS policy enforcement,
the version of the security database is displayed. Otherwise displays N/A.
Total number of interrupts.
Interrupts that are not counted elsewhere.