Enabling And Disabling Failback On An External Port (N_Port) - Dell PowerEdge M420 Administrator's Manual

8/4 gbps fc san module administrator's guide
Hide thumbs Also See for PowerEdge M420:
Table of Contents

Advertisement

FIGURE 6

Enabling and disabling Failback on an external port (N_Port)

Use the following steps to enable or disable Failback on external ports.
1. Connect to the FC SAN Module and log in using an account assigned to the admin role.
2. Enter the ag
3. Use the following commands to enable or disable Failback:
Dell 8/4Gbps FC SAN Module Administrator's Guide
53-1001345-01
Blade Servers
Blade_1
F_1
Blade_2
F_2
Blade_3
F_3
Blade_4
F_4
Blade_5
F_5
Blade_6
F_6
Blade_7
F_7
Blade_8
F_8
Failback behavior
failbackshow n_portnumber command to display the failover setting.
--
switch:admin> ag --failbackshow 13
Failback on N_Port 13 is not supported
Enter the ag
failbackenable n_portnumber command to enable failback.
--
switch:admin> ag --failbackenable 13
Failback policy is enabled for port 13
Enter the ag --failbackdisable n_portnumber command to disable failback.
switch:admin> ag --failbackdisable 13
Failback policy is disabled for port 13
Example 3
FC SAN Module
N_1
N_2
N_3
N_4
Failback
Fabric
Edge Switch
(Switch_A)
F_A1
NPIV
enabled
F_A2
NPIV
enabled
Edge Switch
(Switch_B)
F_B1
NPIV
enabled
F_B2
NPIV
enabled