Cf_Coltemp Command; Cf_Nzred Command; Cf_Progv Command - Canon LV-7575 Specifications

Lv-7575 expand serial command functional specifications
Hide thumbs Also See for LV-7575:
Table of Contents

Advertisement

LV-7575 Expand Serial Command Functional Specifications

8.4.8 CF_COLTEMP Command

Command
"CF_COLTEMP_%1" [CR]
"000" ------------------------------ Xlow
"001"------------------------------- Low
%1
"002"------------------------------- Mid
"003"------------------------------- High
Set Color Temperature (Available only in the normal Power ON status)
The value set by this command will not be stored in the projector's memory.
Details
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Standby mode.)
Acceptable
Response
Unacceptable

8.4.9 CF_NZRED Command

Command
"CF_NZRED_%1" [CR]
"OFF" ---------------- Cancel Noise Reduction
"L1" ------------------- Set Noise Reduction to L1
%1
"L2" ------------------- Set Noise Reduction to L2
"UP" ------------------ Switch setting forward direction (OFF→L1→L2→OFF)
"DN" ------------------ Switch setting backward direction (OFF→L2→L1→OFF)
Set Noise Reduction level (Available only in the normal Power ON status)
The value set by this command will not be stored in the projector's memory
Details
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It returns to the original setting in Standby mode as well.)
Acceptable
Response
Unacceptable

8.4.10 CF_PROGV Command

Command
"CF_PROGV_%1" [CR]
"ON" ----------------- Set Progressive scan to On.
"FILM" --------------- Set Progressive scan to Film.
%1
"OFF" ---------------- Set Progressive scan to OFF.
"UP" ------------------ Switch setting forward direction (OFF→ON→FILM→OFF)
"DN" ------------------ Switch setting backward direction (OFF→FILM→ON→OFF)
Set Progressive scan mode. (Available only in the normal Power ON status)
The value set by this command will not be stored in the projector's memory.
Details
Therefore, when the power is turned to ALL OFF status, the value returns to the
original setting. (It is stored in Standby mode.)
Acceptable
Response
Unacceptable
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
"000" [CR]
"Error Code" [CR]
20/71