Cr_On-Sta Command; Cr_P-Mane Command; Cr_P-Manetime Command; Cr_Fanspeed Command - Canon LV-7575 Specifications

Lv-7575 expand serial command functional specifications
Hide thumbs Also See for LV-7575:
Table of Contents

Advertisement

LV-7575 Expand Serial Command Functional Specifications

9.11.10 CR_ON-STA Command

Command
"CR_ON-STA" [CR]
Details
Get setting status of Power ON Start
Acceptable
Response
Unacceptable

9.11.11 CR_P-MANE Command

Command
"CR_P-MANE" [CR]
Details
Get setting status of Power management
Acceptable
Response
Unacceptable

9.11.12 CR_P-MANETIME Command

Command
"CR_P-MAETIME" [CR]
Details
Get setting time for starting Power Management function
Acceptable
Response
Unacceptable

9.11.13 CR_FANSPEED Command

Command
"CR_FANSPEED" [CR]
Details
Get selected Fan Contorol Speed mode.
Acceptable
Response
Unacceptable

9.11.14 CR_KEYDIS Command

Command
"CR_KEYDIS" [CR]
Details
Get status of RC/KEY (valid or invalid)
Acceptable
Response
Unacceptable
"000_%1" [CR]
"ON" -------------------------- Power ON Start is ON
%1
"OFF" ------------------------ Power ON Start is OFF
"?" [CR]
"000_%1" [CR]
"OFF" ------------------------ Power Management is disabled
"READY" -------------------- Power Management is set to Ready
%1
"SHUTDOWN" ------------ Power Management is set to Shut
Down mode
"?" [CR]
"000_%1" [CR]
%1
"001 – 030" ----------------------- 1 to 30 minutes
"?" [CR]
"000_%1" [CR]
"MAX" ------------------------ Max mode is seleted
%1
"NOR" ------------------------ Normal mode is selected
"?" [CR]
"000_%1" [CR]
"NONE" -------------------------- RC and KEY, both are valid
%1
"RC" ------------------------------- RC is invalid
"KEY" ----------------------------- KEY is invalid
"?" [CR]