Functional Execute Command Table; Status Read Command Table - Canon LV-X4 Technical Specifications

Serial functional specification
Hide thumbs Also See for LV-X4:
Table of Contents

Advertisement

SERIAL FUNCTIONAL SPECIFICATION
5. Functional Execution Command Table
Command
C00
Power ON
C01
Power OFF (Quick Power OFF)
C02
Power OFF
C05
Computer 1
C06
Computer 2
C07
Video
C09
Volume +
C0A
Volume -
C0B
Audio Mute ON
C0C
Audio Mute OFF
C0D
Video Mute ON
C0E
Video Mute OFF
C0F
Screen Normal size (4:3)
C10
Screen Wide size (16:9)
C11
Image_ Standard
C12
Image_ High contrast
C13
Image_ Cinema
C14
Image_ Custom
C18
Image_ Blackboard (Green)
C1C
Menu ON
C1D
Menu OFF
C1E
DISPLAY CLEAR
C20
Brightness +
C21
Brightness -
C25
Computer 2_ RGB
C27
Image (Toggle)
C28
ON Start Enable
C29
ON Start Disable

6. Status Read Command Table

Command
CR0
Status Read
CR1
Input Mode Read
CR3
Lamp Time Read
CR4
Setting Read
CR6
Temp Read
Item
Functional Execution & Status Read Command Table
Command
Item
C2A
C2B
C2E
C3A
C3B
C3C
C3D
C3E
C3F
C5A
C8A
C8E
C8F
Function
Item
Power Management Ready
Power Management OFF
Power Management Shut down
C30
D.Zoom +
C31
D.Zoom -
C32
Video_ Auto
C33
Video_ Video
C34
Video_ S-Video
Pointer Right
Pointer Left
Pointer Up
Pointer Down
Mouse Right Click
Enter
C43
Freeze ON
C44
Freeze OFF
C50
Computer 1_ Analog RGB
C51
Computer 1_ Scart
C54
Computer 1_ Component
C59
Page Up
Page Down
C89
Auto PC Adj.
Presentation Timer
Keystone↑
Keystone↓
Note
Page