Fcip Licensing - HP AE370A - Brocade 4Gb SAN Switch 4/12 Administrator's Manual

Hp storageworks fabric os 5.2.x administrator guide (5697-0014, may 2009)
Hide thumbs Also See for AE370A - Brocade 4Gb SAN Switch 4/12:
Table of Contents

Advertisement

FCIP also supports:
Configuration and management of GbE ports and the virtual ports, IP interfaces, and tunnels enabled
by GbE ports
Compression and decompression of Fibre Channel frames moving through FCIP tunnels
NOTE:
off.
Traffic shaping that adheres to a rate limit on a per tunnel basis
FCIP tunnel/GbE port event notification
Fibre Channel Routing Service capabilities over FCIP tunnels

FCIP licensing

To use FCIP, you must first install the FCIP license. Use the licenseShow command to verify the license is
present on both switches used in the FCIP tunnel. For details on obtaining and installing licensed features,
refer to
Maintaining licensed software
FCIP Tunneling concepts
FCIP Tunneling introduces the following concepts (also refer to
Tunnel
An FCIP tunnel carries Fibre Channel traffic (frames) over IP networks such that the Fibre Channel fabric
and all Fibre Channel devices in the fabric are unaware of the presence of the IP network. Fibre
Channel frames "tunnel" through IP networks by dividing frames, encapsulating the result in IP packets
on entering the tunnel, and then reconstructing them as they leave the tunnel.
GbE ports
Two GbE ports are available on the 400 MP Router and 4/256 SAN Director with a B-Series MP
Router blade. These ports support the FCIP feature with link speeds up to 1 Gbit/sec. Each GbE port
(ge0, ge1) supports up to eight FCIP tunnels, for a total of sixteen virtual ports that can be configured
as either VE_Ports, or VEX_Ports.
NOTE:
disabled. Refer to
these ports. You should configure FCIP and the FC-FC Routing Service before enabling the ports.
Refer to
Service.
VE_Port
Special types of ports, called VE_Ports (virtual E_Port), function somewhat like an E_Port. The link
between an VE_Port and a VE_Port is called an
from a 400 MP Router or 4/256 SAN Director with an B-Series MP Router blade. After you configure
the VE_Ports on either two 400 MP Routers or 4/256 SAN Directors with the B-Series MP Router blade,
an FCIP connection is established between them. VE_Ports do not prevent fabric merging.
VEX_Port
A VEX_Port enables FC-FC Routing Service functionality over an FCIP tunnel. VEX_Ports enable
interfabric links (IFLs) so that you can share storage and servers between fabrics without merging those
fabrics. You can have up to eight VEX_Ports per GbE on the 400 MP Router or 4/256 SAN Director
with an B-Series MP Router blade. A VEX_Port can only be connected to a VE_Port. VEX_Port to
VEX_Port tunnels are not supported. There is no trunking through GbE ports that have been configured
as VE_Ports or VEX_Ports.
368 Configuring and monitoring FCIP tunneling
By default, the compression mode of Fibre Channel frames moving through FCIP tunnels is
features, page 33.
The ports on the 400 MP Router and B-Series MP Router blade are initially persistently
Enable the persistently disabled
Using the FC-FC routing
Figure 18
ports, page 371 for information on enabling
service, page 227 for details about configuring FC-FC Routing
interswitch link
on page 289):
(ISL). You can configure multiple ISLs

Hide quick links:

Advertisement

Table of Contents
loading