The following example shows the portShow fcipTunnel command to display IPSec information for
tunnel 0:
switch:admin06> portshow fciptunnel 8/ge0 3 -ipsec
Port: ge0
-------------------------------------------
Tunnel ID 3
Remote IP Addr 192.175.5.200
Local IP Addr 192.175.5.100
Remote WWN Not Configured
Local WWN 10:00:00:05:1e:37:00:20
Compression off
Fastwrite on
Tape Pipelining on
Uncommitted bandwidth, minimum of 1000 Kbps (0.001000 Gbps)
SACK on
Min Retransmit Time 100
Keepalive Timeout 80
Max Retransmissions 9
Status : Active
Uptime 1 day, 23 hours, 24 minutes, 46 seconds
IKE Policy 7
-----------------------------------------
Authentication Algorithm: MD5
Encryption: 3DES
Perfect Forward Secrecy: off
Diffie-Hellman Group: 1
SA Life (seconds): 200000
IPSec Policy 7
-----------------------------------------
Authentication Algorithm: AES-XCBC
Encryption: 3DES
SA Life (seconds): 1500000
Pre-Shared Key 1234567890123456