Viewing Switch Status - HP AE370A - Brocade 4Gb SAN Switch 4/12 Administrator's Manual

Hp storageworks fabric os 5.2.x administrator guide (5697-0014, may 2009)
Hide thumbs Also See for AE370A - Brocade 4Gb SAN Switch 4/12:
Table of Contents

Advertisement

The following example shows a typical boot sequence, including POST messages:
The system is coming up, please wait...
Read board ID of 0x80 from addr 0x23
Read extended model ID of 0x16 from addr 0x22
Matched board/model ID to platform index 4
PCI Bus scan at bus 0
:
:
:
:
:
:
Checking system RAM - press any key to stop test
Checking memory address: 00100000
System RAM test using Default POST RAM Test succeeded.
Press escape within 4 seconds to enter boot interface.
Booting "Fabric Operating System" image.
Linux/PPC load:
BootROM command line: quiet
Uncompressing Linux...done.
Now booting the kernel
Attempting to find a root file system on hda2...
modprobe: modprobe: Can't open dependencies file /lib/modules/2.4.19/modules.dep (No such file or Directory)
INIT: version 2.78 booting
INIT: Entering runlevel: 3
eth0: Link status change: Link Up. 100 Mbps Full duplex Auto (autonegotiation complete).
INITCP: CPLD Vers: 0x95 Image ID: 0x19
uptime: 2008; sysc_qid: 0
Fabric OS (Paulsa45)
Paulsa45 console login: 2005/03/31-20:12:42, [TRCE-5000], 0,, INFO, ?, trace:, trace_buffer.c, line: 1170
2005/03/31-20:12:42, [LOG-5000], 0,, INFO, SWSAN Switch 4/32_P45, Previous message repeat 1 time(s), trace_ulib.c,
line: 540
2005/03/31-20:12:43, [HAM-1004], 219,, INFO, SWSAN Switch 4/32_P45, Processor rebooted - Unknown
SNMP Research SNMP Agent Resident Module Version 15.3.1.4
Copyright 1989, 1990, 1991, 1992, 1993, 1994, 1995, 1996, 1997, 1998, 1999, 2000, 2001 SNMP Research, Inc.
sysctrld: all services Standby
FSSK 2: chassis0(0): state not synchronized
FSSK 2: Services starting a COLD recovery
2005/03/31-20:12:48, [FSS-5002], 0,, INFO, SWSAN Switch 4/32_P45, chassis0(0): state not synchronized, svc.c, line:
318
2005/03/31-20:12:48, [FSS-5002], 0,, INFO, SWSAN Switch 4/32_P45, Services starting a COLD recovery, mdev.c, line: 638
2005/03/31-20:12:49, [MFIC-1002], 220,, INFO, Paulsa45, Chassis FRU header not programmed for switch NID, using
defaults (applies only to FICON environments).
sysctrld: all services Active
2005/03/31-20:12:50, [DGD-5001], 0,, INFO, SWSAN Switch 4/32_P45, Slot 0 has started POST., main.c, line: 1189
POST1: Started running Thu Mar 31 20:12:51 GMT 2005
POST1: Test #1 - Running turboramtest
POST1: Test #2 - Running portregtest
POST1: Script PASSED with exit status of 0 Thu Mar 31 20:12:54 GMT 2005 took (0:0:3)
POST2: Started running Thu Mar 31 20:12:55 GMT 2005
POST2: Test #1 - Running portloopbacktest (SERDES)
POST2: Test #2 - Running minicycle (SERDES)
POST2: Running diagshow
POST2: Script PASSED with exit status of 0 Thu Mar 31 20:13:12 GMT 2005 took (0:0:17)
2005/03/31-20:13:13, [BL-1000], 221,, INFO, Paulsa45, Initializing Ports... Enabling switch...
2005/03/31-20:13:13, [BL-1001], 222,, INFO, Paulsa45, Port Initialization Completed
2005/03/31-20:13:13, [EM-5012], 0,, INFO, SWSAN Switch 4/32_P45, EM: sent dumpready to ME., em.c, line: 2152
2005/03/31-20:13:13, [DGD-5002], 0,, INFO, SWSAN Switch 4/32_P45, Slot 0 has passed the POST tests., main.c, line: 936
If you choose to bypass POST2, or after POST2 completes, various system services are started and the boot
process displays additional console status and progress messages.

Viewing switch status

Use the switchStatusShow command to display the overall status of the switch, including its power
supplies, fans, and temperature. If the status of any one of these components is either marginal or down,
the overall status of the switch is also displayed as marginal or down. If all components have a healthy
status, the switch displays a healthy status.
To modify the rules used to classify the health of each component use the switchStatusPolicySet
command. To view the rules, use the switchStatusPolicyShow command.
268 Working with diagnostic features

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents