v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 8864," on page 23 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)", that step must be performed only by a
trained service technician.
Error code
Description
00180200
No more I/O space is available for a PCI
adapter.
00180300
No more memory (above 1 MB for a PCI
adapter).
00180400
No more memory (below 1 MB for a PCI
adapter).
00180500
PCI option ROM checksum error.
00180600
PCI built-in self-test failure.
82
IBM System x3850 Type 8864: Problem Determination and Service Guide
Action
1. If the error code indicates a particular PCI slot or
device, remove that device.
2. If the error continues, reseat the following
components:
a. Each adapter
b. (Trained service technician only) PCI board
3. Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.
1. If the error code indicates a particular PCI slot or
device, remove that device.
2. Reseat the following components:
a. Each adapter
b. (Trained service technician only) PCI board
3. Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.
1. Reseat the following components:
a. Each adapter
b. (Trained service technician only) PCI board
2. Replace the components listed in step 1 one at a
time, in the order shown, restarting the server
each time.
1. Remove the failing PCI adapter.
2. Reseat the following components:
a. Each adapter
b. (Trained service technician only) PCI board
3. Replace the components listed in step 2 one at a
time, in the order shown, restarting the server
each time.
1. If the error code indicates a particular PCI slot or
device, remove that device.
Note: Slot 0 indicates the I/O board.
2. Reseat the following components:
a. Each adapter
b. (Trained service technician only, if the
specified board is a FRU). The board
indicated in the error code. (See Chapter 3,
"Parts listing, Type 8864," on page 23, to
determine CRU or FRU status.)
3. Replace the components listed in step 2 one at a
time, in the order shown above, restarting the
server each time.