IBM 88643RU - System x3850 - 8864 Service Manual page 85

Problem determination and service guide
Hide thumbs Also See for 88643RU - System x3850 - 8864:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 8864," on page 23 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)", that step must be performed only by a
trained service technician.
Beep code
One long and two short
beeps
Two long and two short
beeps
No-beep symptoms
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 8864," on page 23 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)", that step must be performed only by a
trained service technician.
No-beep symptom
No beeps occur, and the
system operates
correctly.
No beeps occur after
successful completion of
POST.
No beeps occur, and
there is no video.
Description
Card error.
Card error.
Description
The power-on status is Disabled.
Action
1. Reseat the following components:
a. Microprocessor tray
b. I/O board
2. Replace the following components one at a
time, in the order shown, restarting the
server each time.
a. (Trained service technician only)
Microprocessor tray
b. I/O board
1. Reseat the following components:
a. Microprocessor tray
b. I/O board
2. Replace the following components one at a
time, in the order shown, restarting the
server each time.
a. (Trained service technician only)
Microprocessor tray
b. I/O board
Action
1. (Trained service technician only) Reseat the
operator information panel.
2. (Trained service technician only) Replace
the operator information panel.
1. Run the Configuration/Setup Utility program
and select Start Options; then, set
Power-On Status to Enable.
2. (Trained service technician only) Reseat the
operator information panel.
3. (Trained service technician only) Replace
the operator information panel.
See "Solving undetermined problems" on page
156.
Chapter 5. Diagnostics
69

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x38508864