IBM 88643RU - System x3850 - 8864 Service Manual page 135

Problem determination and service guide
Hide thumbs Also See for 88643RU - System x3850 - 8864:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 8864," on page 23 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)", that step must be performed only by a
trained service technician.
Error code
Description
035-277-001
Adapter Local RAM test error.
035-278-001
Adapter NVSRAM test error.
035-279-001
Adapter Cache test error.
035-280-001
Adapter Drive test error.
035-281-001
Adapter Drive error.
035-282-001
Adapter Parameters set error.
035-283-001
Adapter Battery error.
035-xxx-cnn
c = ServeRAID channel number, nn = SCSI
ID of failing fixed disk drive.
035-xxx-snn
nn = SCSI ID of failing fixed disk.
075-xxx-000
Failed power supply test.
Action
1. Update the RAID controller firmware (see
"Updating the firmware" on page 13).
2. Reseat and, if necessary, replace the RAID
controller.
1. Update the RAID controller firmware (see
"Updating the firmware" on page 13).
2. Reseat and, if necessary, replace the RAID
controller.
1. Update the RAID controller firmware (see
"Updating the firmware" on page 13).
2. Reseat and, if necessary, replace the RAID
controller.
Replace the attached drive.
Replace the attached drive.
1. Update the RAID controller firmware (see
"Updating the firmware" on page 13).
2. Reseat and, if necessary, replace the RAID
controller.
Replace the battery module on the RAID controller.
1. Check the BMC log or system-error log before
replacing a FRU.
2. Reseat and, if necessary, replace the hard disk
drive on channel C, SCSI ID nn.
1. Check the BMC log or system-error log before
replacing a FRU.
2. Reseat and, if necessary, replace the SCSI disk
with ID nn on adapter in slot s
1. Reseat the following components:
a. Power supply
b. (Trained service technician only) Power
backplane
2. Replace the components listed in step 1 one at a
time, in the order shown, restarting the server
each time.
119
Chapter 5. Diagnostics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x38508864

Table of Contents