IBM 436854u - System x3200 M2 5U Mini Tower Server Problem Determination And Service Manual page 231

Service guide
Hide thumbs Also See for 436854u - System x3200 M2 5U Mini Tower Server:
Table of Contents

Advertisement

Table 9. DSA diagnostic messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 3, "Parts listing, System x3200 M2 Types 4367 and 4368," on page 33 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained
service technician.
Message
number
Component
405-903-xxx
Broadcom
Ethernet
device
405-904-xxx
Broadcom
Ethernet
device
Test
State
TestEEPROM
Failed
TestInternalMemory
Failed
Description
Action
1. Make sure that the component firmware
is at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD section
for this component. For the latest level
of firmware, go to http://www.ibm.com/
support/docview.wss?uid=psg1
MIGR-4JTS2T and select your system
to display a matrix of available
firmware.
2. Run the test again.
3. (Trained service technician only)
Replace the system board.
4. Run the test again.
5. If the problem remains, collect the data
from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, see http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
CALL.
1. Make sure that the component firmware
is at the latest level. The installed
firmware level is shown in the DSA
event log in the Firmware/VPD section
for this component. For the latest level
of firmware, go to http://www.ibm.com/
support/docview.wss?uid=psg1
MIGR-4JTS2T and select your system
to display a matrix of available
firmware.
2. Run the test again.
3. (Trained service technician only)
Replace the system board.
4. Run the test again.
5. If the problem remains, collect the data
from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, see http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
CALL.
213
Chapter 5. Diagnostics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X3200 m2X3200 m2 436843674368X3200 m2 type 4367X3200 m2 type 4368

Table of Contents