v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, System x3200 M2 Types 4367 and 4368," on page 33 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
I9990301
Hard disk drive boot sector error.
I9990650
AC power has been restored.
136
System x3200 M2 Types 4367 and 4368: Problem Determination and Service Guide
Action
1. Reseat the following components, depending on
the server model:
v Hot-swap models:
a. Hard disk drive
b. SAS/SATA controller
v Simple-swap models:
a. Hard disk drive
b. Hard disk drive cable
2. Replace the following components one at a time,
depending on the server model, in the order
shown, restarting the server each time:
v Hot-swap models:
a. Hard disk drive
b. Hard disk drive backplane
c. SAS/SATA controller
v Simple-swap models:
a. Hard disk drive
b. Hard disk drive cable
3. (Trained service technician only) Replace the
system board.
1. Reseat the power cords.
2. Check for interruption of the external power.
3. Replace the power cords.