Managing Power Supplies - Cisco DS-C9216I-K9 Configuration Manual

Switch guide
Table of Contents

Advertisement

Configuring Power Supplies
Table 10-3
Scenario
1
2
3

Managing Power Supplies

To manage power supply power attributes, perform the following steps.
Step 1
From the Fabric Manager menu tree, choose Switches > Modules and then click the Power Supplies
tab, or from the Device Manager, choose Physical > Power Supplies. The Information pane from the
Fabric Manager displays power supply power attributes for multiple switches. The dialog box from the
Device Manager displays power supply power attributes for a single switch.
Configure the power attributes for the power supply.
Step 2
Cisco MDS 9000 Fabric Manager Switch Configuration Guide
10-4
You decide to change the switch to redundant mode. Then the current capacity decreases to
2500Watts and the configuration is rejected.
Reason: 2500Watts is less than the system usage (3000Watts).
Summary of Configuration Scenarios for Power Supplies with Different Capacities
Power
Supply 1
Current
(W)
Mode
2500
combined
2500
N/A
2500
combined
2500
N/A
2500
combined
2500
N/A
Power
Current
Supply 2
Usage (W)
(W)
New Mode
2000
1800
N/A
2000
1800
redundant 2500
2000
2200
N/A
2000
2200
redundant 2200
3000
1800
N/A
3000
1800
redundant N/A
Chapter 10
Managing System Hardware
New
Action
Capacity
Taken by
(W)
Switch
3600
Existing
configurati
on.
Power
supply 2 is
shut down
4400
Existing
configurati
on.
The new
capacity is
changed.
3600
Existing
configurati
on.
Rejected,
so the
mode
reverts to
combined
mode.
OL-7753-01