Table D-8: Is the Fan Health LED Green?
Answer
Possible Reasons
No, it is off.
The fan cable or connectors are not
properly connected.
The Integrated Administrator
module is not properly seated.
No, it is red.
At least two fans have failed or are
not properly seated. You no longer
have adequate cooling.
No, it is
At least one redundant fan has
amber.
failed. The system still has
adequate cooling, but is no longer
redundant.
Yes, it is
All fans are functional.
green.
HP ProLiant BL e-Class System Setup and Installation Guide
Possible Solutions
Be sure that the connectors on the fan
cable are properly seated and not
damaged.
Contact HP or an authorized service
provider for parts and service.
Open the fan cage and look for amber
LEDs to determine which fans have
failed. Replace all failed fans.
Contact HP or an authorized service
provider for parts and service.
Contact HP or an authorized service
provider for parts and service.
Check the local or remote console for
error messages. Go to table D-6.
If these steps have not identified the
problem, contact HP or an authorized
service provider for assistance.
Troubleshooting