Troubleshooting
Table D-7: Is the Integrated Administrator Health LED Green?
Answer
Possible Reasons
No, it is off.
The Integrated Administrator is
booting.
No, it is
Software has detected a condition
amber.
within the Integrated Administrator
that requires attention.
No, it is red.
An overtemperature condition was
detected by the sensors on the
Integrated Administrator module.
Yes, it is
Either the Integrated Administrator
green.
console connector or the Integrated
Administrator management
connector is not properly
connected.
D-12
Possible Solutions
If the enclosure is powered up, wait
1 minute while the Integrated
Administrator is booting. If the Integrated
Administrator health LED remains off,
contact HP or an authorized service
provider for parts and service.
Press the reset button on the Integrated
Administrator.
Check the system fans. Go to Table D-8.
Contact HP or an authorized service
provider for parts and service.
Be sure that the room meets temperature
and airflow requirements described in the
HP ProLiant BL e-Class System Overview
and Planning white paper.
Be sure that the system fans are
functioning properly. Go to Table D-8.
If you have a serial device connected to
the Integrated Administrator, be sure that
it is connected with a null-modem cable
and not a straight-through cable. See
Table 3-5 in Chapter 3, "Installing and
Cabling the System."
Be sure that the Integrated Administrator
console connector or the Integrated
Administrator management connector is
securely seated.
Refer to the HP ProLiant BL e-Class
Integrated Administrator User Guide for
further troubleshooting information.