Troubleshooting
8. If the Integrated Administrator is rebooting repeatedly, be sure that it is not
rebooting due to a problem that initiates an Enclosure Self Recovery (ESR)
reboot.
Refer to the HP ProLiant BL e-Class Integrated Administrator User Guide on the
Documentation CD that ships with the enclosure for other continuous rebooting
problems.
9. Restart the enclosure by pressing the enclosure power button on the fan cage on
the rear of the enclosure.
IMPORTANT: If the enclosure does not restart, proceed to Table D-1 of the "Enclosure
Diagnostic Steps" section in this appendix.
10. Be sure that connectors and components are seated properly. Refer to the HP
Servers Troubleshooting Guide on the Documentation CD that ships with the
enclosure.
Enclosure Diagnostic Steps
If the enclosure does not function properly, use Table D-1 to determine appropriate
actions based on the symptoms observed. Start with question 1 and work your way
through the table in order to narrow down possible causes and identify actions or
solutions.
According to the answers you give to the questions in Table D-1, you are directed to
the appropriate table in the section that immediately follows. That table outlines
possible reasons for the problem, options available to assist in diagnosis, possible
solutions, and references to other sources of information.
D-4
CAUTION: Pressing the enclosure power button while the enclosure is running
shuts down the enclosure and all server blades.
HP ProLiant BL e-Class System Setup and Installation Guide