Selector
No.
Erasing time length of ICM tone
1
recorded preceding the tone
detection starting point in the case
|
of automatic line disconnection due
3
to no voice signal received
No. of CNG cycles to be detected
(when the line is connected via the
4
external telephone in the external
5
TAD mode or via the facsimile
equipment in F/T or TAD mode)
Number of DTMF tone signals for
6
inhibiting the detection of CNG
7
during external TAD operation
CNG detection when the external
8
telephone is connected with a line
TAD mode
NOTE: Selectors 1 through 3 are applicable to those models equipped with a built-in TAD.
Selectors 1 through 3:
If the equipment has disconnected the line after detection of disconnection tone in ICM recording, it
erases tone recorded preceding the tone detection starting point for the time length set by these
selectors.
Selectors 4 and 5: No. of CNG cycles to be detected
The equipment interprets a CNG as an effective signal if it detects a CNG signal by the number of
cycles specified by these selectors in any of the following cases:
when the line is connected via the external telephone in the external TAD mode.
when the line is connected via the facsimile equipment in F/T or TAD mode.
Selectors 6 and 7: Number of DTMF tone signals for inhibiting the detection of CNG during external
If the equipment receives this specified number of DTMF tone signals during external TAD
operation, it will not detect CNG afterwards.
If these selectors are set to "1, 1," the CNG detection will not be inhibited.
Selector 8:
CNG detection when the external telephone is connected with a line in TAD
If this selector is set to "0," the equipment will detect a CNG signal only when it detects itself being
called. If the external telephone is connected with a line before the equipment detects itself being
called, the equipment will not longer detect a CNG signal.
If this selector is set to"1," the equipment will detect a CNG signal every time the external telephone
is connected with a line, even without detecting itself being called.
WSW34
Function
Erasing time length of ICM tone recorded preceding the tone detection
starting point in the case of automatic line disconnection due to no voice
signal received
TAD operation
)
(Function setting 12
Setting and Specifications
No. 1
2
3
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
No. 4
5
0
0
:
0
1
:
1
0
:
1
1
:
No. 6
7
0
0
:
0
1
:
1
0
:
1
1
:
0: Only when the
equipment detects
itself being called
V - 46
:
0 sec.
:
1 sec.
:
2 sec.
:
3 sec.
:
4 sec.
:
5 sec.
:
6 sec.
:
7 sec.
0.5
(A)
1
(B)
1.5
(C)
2
(D)
3
2
1
OFF
1: Always