Figure 14 Battery module
1. Status indicator
3. Battery 0
The table below describes the battery status indicators. When a battery is first installed, the fault
indicator goes on (solid) for approximately 30 seconds while the system discovers the new battery.
Then, the battery status indicators display the battery status as described in the table below.
Table 8 Battery status indicators
Status indicator
On
Flashing
Off
Off
Flashing (fast)
Flashing

HSV controller cabling

All data cables and power cables attach to the rear of the controller. Adjacent to each data
connector is a two-colored link status indicator.
presented by these indicators.
18
EVA6400/8400 hardware
Fault indicator
Off
Normal operation. A maintenance charge process keeps the battery fully
charged.
Off
Battery is undergoing a full charging process. This is the indication you
typically see after installing a new battery.
On
Battery fault. The battery has failed and should be replaced.
Flashing
The battery has experienced an over temperature fault.
Flashing (fast)
Battery code is being updated. When a new battery is installed, it may
be necessary for the controllers to update the code on the battery to the
correct version. Both indicators flash rapidly for approximately 30
seconds.
Flashing
Battery is undergoing a scheduled battery load test, during which the
battery is discharged and then recharged to ensure it is working properly.
During the discharge cycle, you will see this display. The load test occurs
infrequently and takes several hours.
2. Fault indicator
4. Battery 1
Description