General Water Chemistry - Hayward Pro Logic Installation Manual

Automation and chlorination
Hide thumbs Also See for Pro Logic:
Table of Contents

Advertisement

if AQL-SS-6B is connected
6B Spa Config.
Push to access the 6 Button Spa Side Remote options
+ to view/change
Move to previous/next configuration menu
Select 6B Spa
Rotates between all available remotes
A
Move to next menu item
Rotates between System Off, Pool/Spa, Filter, Lights, Heater1,
6B A, Button 1
Aux1 and Aux2
Pool/Spa
Move to previous/next menu item or next configuration menu
Select 6B Spa
This menu only appears if more than one AQL-SS-6B is detected at power up. Select which of the available
remote controls (A, B or C) is to be configured.
6B A, Button 1
This menu allows the user to map each button of the AQL-SS-6B to one of the standard Pro Logic
functions. The default selections are: Button 1 - Pool/Spa, Button 2 - Filter, Button 3 - Lights, Button 4 -
Heater1, Button 5 - Aux1 and Button 6 - Aux2.
Toggle between Enabled (default) and Disabled Remote Menus
Remote Menus
Enabled
Move to previous/next configuration menu
This feature will prevent unauthorized access to the Settings, Timers, and Configuration menus from any
of the Pro Logic's remote display/keypads. When disabled, the remote display/keypads will only show the
default menu and allow on/off control via the pushbuttons. Note that the function of the Pro Logic's built-
in display/keypad is unchanged by this selection. Once disabled, the only way to enable "Remote
Menus" is to use the local display/keypad.
Toggle between 7-day (default) and Weekend/Weekday time options
All Timeclocks
7-day
Move to previous/next configuration menu
This selection affects ALL of the timeclock logic in the Pro Logic. If "7-day" is selected, each timeclock will
have one set of turn-on/turn-off settings that operate every day of the week. If "Weekend/Weekdays"
option is selected then the user can enter one set of turn-on/turn-off times for the weekend (fixed as
Saturday/Sunday) and another set of turn-on/turn-off times for weekdays (Monday through Friday).
Toggle between 12 hour AM/PM (default) and 24 hour time format options
Time Format
12 hour AM/PM
Move to previous/next configuration menu
Toggle between ºF and PPM (default) and ºC and g/L (Metric) options
Units
ºF and PPM
Move to previous/next configuration menu
if any output is configured as a
variable speed pump
Toggle between % and RPM
VSP Speed
%
Move to previous/next configuration menu
This is the unit of measure for displaying the speed of the variable speed pump. Select % of maximum
speed (3450 RPM) or revolutions per minute (RPM).
29
4. Electrical Wiring (page 10)
Main service
Grounding and bonding
Circuit breakers
Pro Logic control power
High Voltage pool equipment
Low voltage wiring (temperature sensors, flow
switch, etc.)
1. Preparing Pool/Spa Water

General Water Chemistry

Salt is required only if you are using the chlorinator features on the Pro Logic Control. If you are NOT using the
chlorinator, it is recommended that you follow all of the other chemistry recommendations besides salt. Refer to the
description of the Pro Logic configuration menu for information on enabling/disabling the chlorinator (see page 20).
Water Chemistry
The table below summarizes the levels that are recommended by the Association of Pool and Spa Professionals
(APSP). The only special requirements for the Pro Logic are the salt level and stabilizer.
Saturation index
The saturation index (Si) relates to the calcium and alkalinity in the water and is an indicator of the pool water "bal-
ance". Your water is properly balanced if the Si is 0 ±0.2. If the Si is below -0.2, the water is corrosive and plaster
pool walls will be dissolved into the water. If the Si is above +0.2, scaling and staining will occur. Use the chart below
to determine the saturation index.
Si = pH + Ti + Ci + Ai - 12.1
Calcuim
ºC
ºF
Ti
Hardness
12
.3
53
16
60
.4
19
66
.5
24
.6
76
29
84
.7
34
94
.8
39
.9
103
How to use: Measure pool pH, temperature, calcium hardness,
and total alkalinity. Use the chart above to determine Ti, Ci,and
Ai from your measurements. Insert values of pH, Ti, Ci and Ai
into the above equation. If Si equals .2 or more, scaling and
staining may occur. If Si equals -.2 or less corrosion or irritation
may occur.
CORROSIVE
5. Pro Logic control configuration (page 20)
6. System Startup and checkout (page30)
Total
Ci
Ai
Alkalinity
75
1.5
75
1.9
100
1.6
100
2.0
125
1.7
125
2.1
1.8
2.2
150
150
1.9
2.3
200
200
250
2.0
250
2.4
300
2.1
300
2.5
400
2.2
400
2.6
600
2.4
600
2.8
800
2.5
800
2.9
-.2
0
.2
SCALING
OK
2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pro logic pl-p-4

Table of Contents