General Purpose Outlet; Pro Logic Control Power; High Voltage Pool Equipment - Hayward Pro Logic Installation Manual

Automation and chlorination
Hide thumbs Also See for Pro Logic:
Table of Contents

Advertisement

General Purpose Outlet

If desired, a duplex receptacle with weatherproof cover (supplied by installer) may be installed in the knockouts on
the lower right side of the Pro Logic enclosure. Per code, the receptacle should be a GFCI type. Alternatively,
connect a standard receptacle to a GFCB.

Pro Logic Control Power

The Pro Logic requires 120VAC, 2A power to operate the control logic circuits and the chlorinator. This power
should be connected to one of the circuit breakers.
!
WARNING: 120VAC only (permanent damage if connected to 240V)
Field
Wired
High Voltage (120/240V) Pool Equipment
All Pro Logic relays are double pole (they make/break both "legs" of 240V circuits) and are rated at 3HP/30A at
240V (1½HP/30A at 120V). Refer to the diagram below for typical relay wiring.
240 VAC
Load
Wiring relays for 240 VAC
Pool Equipment
Factory
Prewired
120, 2VA
L1
Neutral
120 VAC
120 VAC
Load
Load
Wiring relays for 120 VAC
Wiring GFCB for 120 VAC
Pool Equipment
Pool Equipment
11
5. Configuration Menu
After plumbing and wiring are complete, the Pro Logic MUST BE CONFIGURED before attempting to operate.
Configuration information is entered at the keypad and "tells" the Pro Logic what equipment is connected and how
each should be controlled.
Accessing the Configuration Menus
Configuring the Pro Logic requires that you navigate through the Configuration Menu and input various informa-
tion. For more detailed information about using the Pro Logic menu system, refer to the Operation Manual.
To access the Configuration Menu
Configuration
Press repeatedly until "Configuration Menu" is displayed
Menu-Locked
Press BOTH buttons SIMULTANEOUSLY for 5 seconds to unlock
Configuration
Move to configuration menu items
Menu-Unlocked
NOTE: The configuration menu automatically "locks" after 2 minutes of no buttons being pressed to
prevent unauthorized people from changing the control logic inadvertently and possibly damaging
the pool equipment or causing a "call back" to fix the configuration.
Configuration Menu Items
Each item needs to be programmed and may contain additional sub-menu items. Refer to the following pages for
information on programming.
Chlor. Config.
Chlor. Config.
Push to access Chlorinator option
+ to view/change
+ to view/change
Move to next configuration menu
Toggle between Chlorinator Enabled and Disabled (default)
Chlorinator
Chlorinator
Move to next menu item
Enabled
Enabled
Display
Display
Toggle between Display Salt (default) and Minerals
Salt
Salt
Move to previous/next configuration menu
Cell Type
Cell Type
Rotates between available Cell types
T-CELL-15
T-CELL-15
Move to next menu item
Chlorinator
Requires the use of a chlorinator cell and P-KIT sold separately. If the chlorinator is enabled, then
the cell and flow switch must also be installed and the Pro Logic will automatically chlorinate both the
pool and spa according to the desired output setting (see Settings Menu in the Operation manual). If
disabled (default), all displays relating to the chlorinator will be suppressed. When the chlorinator is
enabled, the Pro Logic will automatically detect and control any Aqua Rite(s) installed in the system.
Display
Allows for the display of salt (default) or mineral values.
Cell Type Selection
The Cell Type Menu appears after "Display Salt/Minerals" in the Chlorinator Configuration Menu.
The options are T-CELL-15 (default), T-CELL-9, T-CELL5 or T-CELL-3. Make the proper selection
based on the chlorinator cell that is used in your system. Refer to the information below.
"T-CELL-3" = T-CELL-3, GLX-CELL-3-W
"T-CELL-5" = GLX-CELL-5, GLX-CELL-5-W
"T-CELL-9" = T-CELL-9, GLX-CELL-9-W
"T-CELL-15" = T-CELL-15, GLX-CELL-15-W
Chemistry Config.
Press to access Chemistry Config. Wizard
Wizard + to enter
Move to previous/next menu item
Chemistry Configuration Wizard
Requires use of the optional AQL-CHEM Sensing Kit. Following the steps of the Chemistry Config.
Wizard will set up the AQL-CHEM to sense ORP and pH levels and, if chlorination is used, can
configure the Pro Logic to generate the correct amount of chlorine to properly sanitize the pool. Refer
to the AQL-CHEM manual for more detailed information.