Main Service; Grounding And Bonding; Circuit Breaker Installation And Wiring - Hayward Pro Logic Installation Manual

Automation and chlorination
Hide thumbs Also See for Pro Logic:
Table of Contents

Advertisement

Pool/Spa Config.
Push to access Pool/Spa options
+ to view/change
Move to previous/next configuration menu
Rotates between Pool Only (default), Spa Only and
Pool/Spa Setup
Pool and Spa
Pool and Spa
Move to next menu item
if "Pool and Spa" is selected
Spa - CountDn
Adjust time setting (Manual On/Off, 0:05, 0:10, 0:15..., (default is 4:00))
00:30
Move to next menu item
if "Pool and Spa" is selected
Spa Spillover
Toggle between Enabled and Disabled
Enabled
Move to next menu item or previous/next configuration menu
if "Pool and Spa" is selected and
if "Spa Spillover" is enabled
Filter Operation
Toggle between Pool Only
Spa Spillover
Move to previous/next configuration menu
if "Pool Only" or "Spa Only" is selected
V1=Aux1, V2=Aux2
Toggle between Enabled and Disabled (default)
Disabled
Move to previous/next configuration menu
if "Pool and Spa" is selected
Filter Off Valve
Toggle between Enabled
Change: Enabled
Move to previous/next configuration menu
Pool/Spa Setup
If "Pool Only" or "Spa Only" are selected, then the pool/spa valves are not needed and pushing the POOL/
SPA button on the display/keypad will have no effect. If "Pool and Spa" is selected, then the pool/spa
suction and return valve actuators should be connected to the Pro Logic. Pressing the POOL/SPA button
on the display/keypad will allow the homeowner to alternate between pool and spa operation.
Spa CountDn
This menu will appear only if Pool/Spa Setup is set to "Pool and Spa". This setting is the time, after you
manually switch the Pool/Spa valves to "Spa Only", until the Pro Logic automatically returns the valves to
their previous positions. It is programmed in increments of 5 minutes, from "Manual On/Off" (0 minutes) to
"21:00" (21 hours). The filter is forced on during this time period.
Spa Spillover
When spa spillover is "Enabled" and "Pool and Spa", the homeowner will be able to rotate through "Pool
Only" (both suction and return valves switched to pool), "Spa Only" (both suction and return valves
switched to spa) and "Spillover" (suction valve switched to pool and return valve switched to spa) by
successive presses of the "Pool/Spa button.
Filter Operation
If "Spa Spillover" is selected, the Pro Logic will automatically switch the pool/spa suction and return
valves to "spillover" at the start of the programmed pool filtering time period or when the super-chlorinate
function is turned on. The valves will remain in this position for the remainder of the super-chlorinate
period. This option is usually preferable because both the pool and spa water will be filtered and sanitized.
If "Pool Only" is selected, then the Pro Logic will switch the pool/spa valves to the "pool only" position
at the start of the programmed pool filtering time period or when the super-chlorinate function is turned on.
This may be desirable on some systems with in-floor cleaners because it allows the cleaner to operate all
the time the pool is being filtered and/or the super chlorinate is running.
V1=Aux1, V2=Aux2
This menu appears only if the Pool/Spa Setup is "Pool Only" or "Spa Only". When enabled, Valve 1
(return) will follow the Aux1 output and Valve 2 (suction) will follow the Aux2 output. When disabled
(default), the return and suction pool/spa valves function normally.
Filter Off Valve Change
This menu appears only if Pool/Spa setup is set to "Pool and Spa - Std". When enabled (default), the filter
pump will shut off for 35 seconds whenever the Pool/Spa valves are turning. The pump will NOT shut off
when a heater is in Heater Cooldown mode.
(default)
Spa Spillover
(default)
and Spa Spillover options
(default)
and Disabled
21
4. Electrical Wiring
Wireless Base
Receiver Connector
Remote Keypad
Temp Sensor Inputs
External Input
Heater Output
x
Valve Connectors
x
Flow Switch
Cell Connector
Subpanel
The Pro Logic Control Center requires both high and low voltage connections. Low voltage connections will be made
to actuators, sensors, remote keypad, etc. High voltage connections will be made to pumps, lights, etc., as well as
providing direct input power to the Control Center. Always:
-Ensure that Power is disconnected prior to doing any wiring
-Follow all local and NEC (CEC if applicable) codes
-Use copper conductors only
Main Service (Power to the Circuit Breaker Subpanel)
The Pro Logic circuit breaker subpanel is rated for 100A service. Run properly rated conductors (L1, L2, N, and
ground) from the primary house electrical panel to the main power connections on the Pro Logic circuit breaker base.
The connection at the main house panel should be to a 240VAC circuit breaker rated at 100A maximum.

Grounding and Bonding

Connect a ground wire from the primary electrical panel to the Pro Logic ground bus bar. Also ground each piece of
high voltage (120 or 240VAC) equipment that is connected to the Pro Logic control relays or circuit breakers. The
Pro Logic should also be connected to the pool bonding system by an 8AWG (6AWG for Canada) wire. A lug for
bonding (2 for Canada) is provided on the outside/bottom of the Pro Logic enclosure.

Circuit Breaker Installation and Wiring

Circuit breakers are to be supplied by the installer. Refer to the circuit breaker chart below for a list of suitable circuit
breakers that can be used. Follow the code and the circuit breaker manufacturer's rating requirements regarding the
size and temperature rating for wiring. Note that some pool equipment may be required to be connected to ground
fault circuit breakers—check local and NEC (CEC) codes.
SUITABLE LISTED BREAKERS
Manufacturer
Single Double
Cutler-Hammer
BR
BR
Murray
MP-T
MP-T
QP
QP
Siemens
Square D
HOM
HOM
Thomas & Betts
TB
TB
G.E.
THQL
THQL
AQL-CHEM Connector
"Local" Display
High Voltage
Relays
Control Power
Input
pH Dispense
Output
Bonding Lug(s)
Ground Bus Bar
Tightening
Torque
Twin
Quad
GFCB
Filler Plates
BRFP
BRD
BRD
GFCB
25lb-in
MH-T
MP-GT
LX100FP
25lb-in
MH-T
QT
QT
QPF
QF3
25lb-in
HOMT
HOMT
HOM-GFI
HOMFP
25lb-in
FP-1C-TB
TBBD
TBBQ
GFB
25lb-in
THQL-GF
TFH
25lb-in
10