HP Integrity BL890c - i2 Server Manual page 92

Virtual connect ethernet cookbook:single and multi enclosure domain (stacked) scenarios
Hide thumbs Also See for Integrity BL890c - i2 Server:
Table of Contents

Advertisement

Defining a new vNet via GUI
Create a vNet and name it "vNet-PROD"
On the Virtual Connect Manager screen, click Define, Ethernet Network to create a vNet
Ether the Network Name of "vNet-PROD"
a.
Select Add Port, then add the following ports;
a.
b.
Leave Connection Mode as Auto
Select Apply
Note: By connecting TWO Uplinks from this vNet we have provided a redundant path to the network. As
each uplink originates from a different VC module, one uplink will be Active and the second will be in
Standby. This configuration provides the ability to lose an uplink cable, network switch or depending on
how the NICs are configured at the server (teamed or un-teamed), even a VC module.
Note: Smart Link – In this configuration Smartlink should NOT be enabled. Smartlink is used to turn if
downlink ports within Virtual Connect, if ALL available uplinks to a vNet or SUS are down.
Defining a new vNet via CLI
The following command(s) can be copied and pasted into an SSH based CLI session with Virtual Connect
# Create the vNet "vNet-PROD" and configure uplinks as discussed above
add Network vNet-PROD SmartLink=Disabled
add uplinkport enc0:1:1 Network=vNet-PROD speed=auto
add uplinkport enc0:2:1 Network=vNet-PROD speed=auto
set network vNet-PROD Private=Enabled
Select Private Networks
Enclosure 1, Bay 1, Port 1
Enclosure 1, Bay 2, Port 1
Scenario 1:7 – Private Networks (Simple vNet) 92