Juniper JUNOSE SOFTWARE 10.2.2 - RELEASE NOTES 6-4-2010 Release Note page 68

For e series broadband services routers
Table of Contents

Advertisement

JUNOSe 10.2.2 Release Notes
60
Errata
In addition, the Note in this command section inaccurately states that the E
Series router supports graceful restart only as a receiving peer and not as a
restarting peer. However, E Series routers have supported graceful restart as
restarting peers, in addition to functioning as receiving peers, since JUNOSe
Release 5.1.0.
The JUNOSe Command Reference Guide A to M omits the description of the
dns-domain-search command, beginning with JUNOSe Release 10.1.0 in
which it was introduced.
The dns-domain-search command is available in IPv6 Local Pool Configuration
mode. You can use this command to specify a list of domain names in the IPv6
local address pool to be returned to clients in DHCPv6 responses as part of the
Domain Search List option. The no version removes the configured domain
name.
NOTE:
You can configure one domain name per line. Enter the command on
separate lines to configure additional domain names.
The syntax for this command is:
[ no ] dns-domain-search domainName
where:
domainName—Domain name that the DHCPv6 client uses when it resolves
hostnames with the DNS server. You can specify a maximum of four DNS
domains for the search list of an IPv6 local pool; maximum of 32 characters.
The description of the neighbor graceful-restart command in the JUNOSe
Command Reference N to Z incorrectly states that graceful restart is enabled by
default. The correct default behavior is that graceful restart is disabled. This
default behavior has been applicable since the time this command was
introduced in JUNOSe Release 7.1.0.
The description of the shaping-rate command in the JUNOSe Command
Reference Guide N to Z incorrectly states the range and units for the shapingRate
argument. The correct range for the shapingRate argument is 1–1000000000
bps/kbps. You can set the shaping rate to vary from 1 bps to 1000 gbps (which
is denoted by entering 1000000000 kbps in the CLI for this command).
The tables in the Interface Types and Specifiers section of Chapter 1, Command
Reference Topics, in the JUNOSe Command Reference Guide erroneously state that
the maximum number of PPPoE subinterfaces per Ethernet (GE/FE) line
module is 4094. The correct number for an ERX router is 8000 and for an E120
or E320 router, it is 16,000.