EC Messages
Error Message EC-5-PORTDOWN: Shutting down [chars] as its port-channel is
admin-down.
Explanation
administrative state of its aggregate port. If the administrative state of the aggregate port is down,
the administrative state of the port is also forced to be down. [chars] is the physical interface.
Recommended Action
to activate the aggregation port.
Error Message EC-5-STAYDOWN: [chars] will remain down as its port-channel [chars] is
admin-down.
Explanation
of the affected port. If the aggregation port is administratively down, all ports in the aggregation port
are forced to be administratively down. The first [chars] is the physical interface, and the second
[chars] is the EtherChannel.
Recommended Action
port to activate (unshut) the aggregation port.
Error Message EC-5-STAYDOWN: no-shut not allowed on [chars]. Module [dec] not online.
Explanation
enabled by using the no shutdown interface configuration command because it is a member of an
EtherChannel group and that EtherChannel group has been administratively shut down. The
interface has an EtherChannel configuration, but no information is available yet about its port
channel. [chars] is the interface, and [dec] is the module.
Recommended Action
port-channel setting of the EtherChannel.
Error Message EC-5-UNBUNDLE: Interface [chars] left the port-channel [chars].
Explanation
[chars] is the physical interface, which can be a switch port or a routed port, and the second [chars]
is the EtherChannel.
Recommended Action
Error Message EC-5-UNSUITABLE: [chars] will not join any port-channel, [chars].
Explanation
is configured for PortFast, as a VLAN Membership Policy Server (VMPS), for 802.1x, as a voice
VLAN, or as a Switched Port Analyzer (SPAN) destination port. All of these are unsuitable
configurations for EtherChannels. The first [chars] is the interface name, and the second [chars]
describes the details of the unsuitable configuration.
Recommended Action
Catalyst 3750 Switch System Message Guide
2-22
This message means that the administrative state of the port is controlled by the
Enter the no shutdown interface configuration command on the aggregate port
This message means that the administrative state of the aggregation port overrides that
Enter the no shutdown interface configuration command on the aggregation
This message means that an interface with an EtherChannel configuration cannot be
No action is required. Wait until the module is online to find out the
This message means that the listed interface left the specified EtherChannel. The first
No action is required.
This message means that one of the interfaces cannot join the EtherChannel because it
Reconfigure the port; remove the unsuitable configuration.
Chapter 2
Message and Recovery Procedures